{"product_id":"baxter-prismaflex-hf1400-hemofilter-set-107142","title":"Baxter Prismaflex HF1400 Hemofilter Set 107142 – CRRT, 4\/Case","description":"\u003ch2\u003e\u003cspan\u003eBaxter Prismaflex HF1400 Hemofilter Set 107142 – CRRT, 4\/Case\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBaxter Prismaflex HF1400 Hemofilter Set (107142)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a sterile, single-use extracorporeal circuit and hemofilter set designed for continuous renal replacement therapy (CRRT) and fluid management in critical care settings. Featuring a 1.4 m² polyarylethersulfone (PAES) hollow-fiber membrane, the HF1400 set is designed for use with compatible Prismaflex and PrisMax renal therapy systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePart of the Baxter\/Gambro Prismaflex product family, this \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCRRT hemofilter set\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e supports continuous fluid management and renal replacement therapies prescribed for patients with acute renal failure, fluid overload, or both.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Prismaflex HF1400 is a disposable treatment set, not a dialysis machine.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features and Benefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1.4 m² Membrane Surface Area:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Features a larger effective filtration surface area than the Prismaflex HF1000 set.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePAES Hollow-Fiber Membrane:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Polyarylethersulfone membrane technology designed for extracorporeal filtration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDesigned for CRRT:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports prescribed continuous renal replacement therapies and fluid management.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eIntegrated Extracorporeal Circuit:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes the hemofilter and associated tubing components for compatible therapy systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePrismaflex System Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for use with compatible Prismaflex control units and appropriately cleared PrisMax systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMinimum Blood Flow Rate of 100 mL\/min:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports operation within the manufacturer's specified parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSterile, Single-Use Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ethylene oxide sterilized for professional clinical use.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInstitutional Packaging:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Available in a manufacturer case quantity of four sets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eBaxter Prismaflex HF1400 Product Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBaxter \/ Gambro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Name\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePrismaflex HF1400 Set\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer Part Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e107142\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCRRT Hemofilter and Extracorporeal Circuit Set\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHemofilter Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHF1400\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEffective Membrane Surface Area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.4 m²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMembrane Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyarylethersulfone (PAES)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFiber Internal Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e215 µm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFiber Wall Thickness\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 µm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter Housing and Headers\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolycarbonate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter Potting Compound\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyurethane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTubing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlasticized PVC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSterilization Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthylene Oxide (EtO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Blood Flow Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mL\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Transmembrane Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 mmHg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Filter Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 mmHg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatible Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePrismaflex and appropriately cleared PrisMax systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUse\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Use\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer Packaging\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Sets per Case\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrescription Required\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003ePrismaflex HF1400 for Continuous Renal Replacement Therapy\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePrismaflex HF1400 CRRT hemofilter set\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed for use in continuous renal replacement therapies, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSCUF:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Slow Continuous Ultrafiltration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCVVH:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Continuous Venovenous Hemofiltration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCVVHD:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Continuous Venovenous Hemodialysis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCVVHDF:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Continuous Venovenous Hemodiafiltration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe HF1400 is used with compatible Prismaflex or PrisMax control units under the direction of qualified healthcare professionals. Therapy selection, blood flow settings, and operating parameters must follow the manufacturer's instructions and prescribed treatment protocol.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePrismaflex HF1400 vs. HF1000: What's the Difference?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Baxter Prismaflex HF1400 (107142) and HF1000 (107140) are both disposable CRRT hemofilter sets, but they have different membrane surface areas and minimum blood flow specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eHF1400 (107142)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eHF1000 (107140)\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMembrane Surface Area\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.4 m²\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.1 m²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMembrane Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePAES\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePAES\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Blood Flow Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mL\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mL\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Transmembrane Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 mmHg\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 mmHg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer Case Quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Sets\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Sets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003eThe appropriate hemofilter should be selected according to the prescribed therapy, patient requirements, system compatibility, and manufacturer instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat is Baxter Prismaflex 107142?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBaxter 107142 is the Prismaflex HF1400 disposable hemofilter and extracorporeal circuit set used with compatible continuous renal replacement therapy systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eIs the Prismaflex HF1400 a dialysis machine?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNo. The HF1400 is a disposable CRRT hemofilter set. The Prismaflex or PrisMax control unit is a separate device and is not included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the membrane surface area of the HF1400?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Prismaflex HF1400 has an effective membrane surface area of 1.4 m².\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between Prismaflex HF1000 and HF1400?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe HF1400 has a 1.4 m² membrane surface area and a minimum blood flow rate of 100 mL\/min. The HF1000 has a 1.1 m² membrane surface area and a minimum blood flow rate of 75 mL\/min.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eIs the Prismaflex HF1400 compatible with PrisMax?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe HF1400 is indicated for use with Prismaflex and with PrisMax in countries where the PrisMax system is appropriately cleared or registered. Always verify compatibility with the manufacturer's instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHow many Baxter Prismaflex HF1400 sets come in a case?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe manufacturer case quantity is four disposable sets.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eIs Baxter 107142 reusable?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNo. The Prismaflex HF1400 is a sterile, single-use medical device.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eOrder Baxter Prismaflex HF1400 CRRT Supplies from Lexicon Medical Supply\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eLexicon Medical Supply offers Baxter\/Gambro renal therapy products and medical supplies for hospitals, dialysis programs, intensive care units, and other healthcare facilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eContact Lexicon Medical Supply for availability, institutional purchasing inquiries, and case quantities of the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBaxter Prismaflex HF1400 Hemofilter Set 107142\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eFor prescription use only. Intended for use by trained healthcare professionals. Follow the manufacturer's instructions for use, compatibility requirements, and applicable medical-device safety notices.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"Lexicon Medical Supply","offers":[{"title":"Default Title","offer_id":67889139023908,"sku":null,"price":2969.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0744\/8910\/2372\/files\/GMO107142_PRI01.jpg?v=1792886814","url":"https:\/\/www.lexiconsupply.com\/products\/baxter-prismaflex-hf1400-hemofilter-set-107142","provider":"Lexicon Medical Supply","version":"1.0","type":"link"}